General Details
Technical Specifications
Operating temperature | -30 °C … +70 °C |
Bending radius min. | 10 x D |
Impedance | 75 ± 3 Ω |
Capacity | 52 ± 2 pF/m |
Propagation speed | %83 ± 2 |
Insulation resistance min. | 2 G Ω x km |
Operating voltage max. | 1000 V |
Test voltage | 2500 V |
Standards | EN 50117, IEC 61196 |
fire performance | Vertical flame spread EN 60332-1-2 |
Satellite distribution cable usage length | 2150MHz – 40m |
VHF/UHF distribution cable length | 860MHz – 100m |
S-band cable TV distribution cable run length | 470MHz – 140m |
Attenuation @20 °C max | 50 MHz 7,26 dB/100m 200 MHz 14,23 dB/100m 470 MHz 21,91 dB/100m 860 MHz 29,96 dB/100m 1000 MHz 32,43 dB/100m 2150 MHz 48,82 dB/100m 2400 MHz 51,83 dB/100m 3000 MHz 58,59 dB/100m |
return loss | 5-470 MHz > 20 dB 470-1000MHz > 28 dB 1000-2000 MHz > 16 dB 2000-3000 MHz > 15 dB |
Usage areas
Using physical foamed insulation technology, cables with 75 ohm characteristic impedance are used in Cable TV, individual-central antenna and satellite distribution systems and CCTV security camera systems in accordance with EN 50117 standards. Thanks to its small cable diameter, it provides ease of use in electrical installation pipes in flush-mounted walls and ceilings in renovation projects in buildings.
Cable Structure
Conductive | Electrolytic copper wire, Ø 0.64mm (AWG22) Class 1, IEC 60228 |
Insulation | Physically foamed PE, Ø 2.90mm 70°C, EN 50290-2-23 |
Screen | Al-Pet foil min.100% coverage aluminum wire mesh |
Sheath | PVC – RAL 9003 White, Ø 4,30×8,80mm TM51 70°C, EN 50290-2-22 |
Proposal form
Comments