General Details
Technical Specifications
Operating Temperature | -30 °C … +70 °C |
Bending radius min. | 10 x D |
Impedance | 75 ± 3 Ω |
Capacity | 52 ± 2 pF/m |
Velocity of propagation | %86 ± 2 |
Insulation resistance min. | 2 G Ω x km |
Operatin voltage max. | 1300 V |
Test voltage | 3000 V |
Standards | EN 50117, IEC 61196 |
Fire performans | Vertical flame spread EN 60332-1-2 |
Satellite distribution2) | 2150MHz – 67m |
VHF/UHF distribution3) | 860MHz – 167m |
S-band Cable TV distribution3) | 470MHz – 230m |
Attenuation @20°C max | 50 MHz 4,30 dB/100m 200 MHz 8,40 dB/100m 470 MHz 13,0 dB/100m 860 MHz 18,0 dB/100m 1000 MHz 19,5 dB/100m 2150 MHz 29,7 dB/100m 2400 MHz 31,7 dB/100m 3000 MHz 36,0 dB/100m |
Return Loss | 5-470 MHz > 23 dB 470-1000MHz > 20 dB 1000-2000 MHz > 18 dB 2000-3000 MHz > 16 dB |
Screen Attenuation | 30-1000MHz ≥ 95 dB 1000-2000 MHz ≥ 85 dB 2000-3000 MHz ≥ 75 dB |
Transfer ımpedance | 5-30MHz ≤ 2,5 mΩ/m |
Screening Class | Class A+ |
Usage areas
Silicone insulated and sheathed cable is used indoors in dry or humid places where the ambient temperature is high, and in environments where there is no mechanical stress. Thanks to its flexible structure, it provides an advantage in application. It is mainly used for measuring, controlling and feeding purposes in engineering projects in foundries, glass and ceramic workshops to be used for feeding resistance and furnaces.
Cable Structure
Conductor | Annealed copper wire Ø 1.13mm |
Insulation | Physically foamed PE Ø 4,80mm |
Screen | Al-Pet-Sy foil 100% coverage tinned copper wire braid 80% coverage Al-Pet foil 100% coverage |
Sheath | White PVC Ø 6,90mm |
Proposal form
Comments