SL200 U26/7

27.09.2021
461
SL200 U26/7

General Details

temperature rangeconstant: -20 °C… +60 °C
active: 0 °C… +50 °C
Bending radius min.constant: min. 4xD
active: min. 8xD
Tensile strength max.60 N
Crush resistance min.1000 N/10cm
Impact resistance min.10 blows
Conductor resistance max.150Ω/km
Resistance imbalance max.3%
Insulation resistance min.5000MΩx m
capacitance nom.50pF/m
Capacity imbalance max.1600pF/km
characteristic impedance100 ± 5 Ω @100MHz
Propagation speed67-69%
Propagation delay max.537 ns/100m
Signal delay max.45 ns/100m
Test voltage1000 V
Operating voltage max.72 V
TCL min.“Level 2”
Coupling attenuation“Type III”
Transfer impedance“Class 2”
Segregation class“b” EN 50174-2

Usage areas

It is a data cable designed for analog and digital signal transmission in audio, video and data applications supporting 100MHz, 1.0Gbit/s 1Gigabit Ethernet in information transmission systems. It meets the structured cabling systems standards, ANSI EIA/TIA 568, ISO/IEC 11801 and EN 50173 Class D class specifications.

IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T

IEEE 802.5 16MB; ISDN; TPDDI; ATM

Power over Ethernet (PoE) / PoE+

Cable Structure

ConductiveStranded electrolytic copper wire, Ø 26/7AWG
InsulationHDPE, TIA 568 isolated color coding 80°C, EN 50290-2-23
SheathLSZH/LS0H – RAL 1015 Cream, Ø 5.0mm 70°C, EN 50290-2-27 PVC – RAL 7001 Grey, Ø 5.0mm TM52 70°C, EN 50290-2-22
Proposal form

    TAGS: SL200 U26/7
    Comments