SL400 SF/U23

27.09.2021
368
SL400 SF/U23

General Details

temperature rangeconstant: -20 °C… +60 °C
active: 0 °C… +50 °C
Bending radius min.constant: min. 4xD
active: min. 8xD
Tensile strength max.100 N
Crush resistance min.1000 N/10cm
Impact resistance min.10 blows
Conductor resistance max.85Ω/km
Resistance imbalance max.2%
Insulation resistance min.5000MΩx m
capacitance nom.50pF/m
Capacity imbalance max.1600pF/km
characteristic impedance100 ± 5 Ω @100MHz
Propagation speed67-69%
Propagation delay max.537 ns/100m
Signal delay max.45 ns/100m
Test voltage1000 V
Operating voltage max.72 V
TCL min.“Level 2”
Coupling attenuation“Type Ib”
Transfer impedance“Class 2”
Segregation class“c” EN 50174-2

Usage areas

temperature rangeconstant: -20 °C… +60 °C
active: 0 °C… +50 °C
Bending radius min.constant: min. 4xD
active: min. 8xD
Tensile strength max.100 N
Crush resistance min.1000 N/10cm
Impact resistance min.10 blows
Conductor resistance max.85Ω/km
Resistance imbalance max.2%
Insulation resistance min.5000MΩx m
capacitance nom.50pF/m
Capacity imbalance max.1600pF/km
characteristic impedance100 ± 5 Ω @100MHz
Propagation speed67-69%
Propagation delay max.537 ns/100m
Signal delay max.45 ns/100m
Test voltage1000 V
Operating voltage max.125 V
TCL min.“Level 2”
Coupling attenuation“Type Ib”
Transfer impedance“Class 2”
Segregation class“c” EN 50174-2

Cable Structure

ConductiveElectrolytic copper wire, Ø 23AWG
InsulationHDPE, TIA 568 isolated color coding 80°C, EN 50290-2-23
Cross SeparatorPE
ScreenAl-Pet foil min.100% coverage Tinned copper wire braid 50% coverage
SheathLSZH/LS0H – RAL 1018 Yellow, Ø 7.6mm 70°C, EN 50290-2-27 PVC – RAL 7001 Grey, Ø 7.6mm TM51 70°C, EN 50290-2-22 PE – RAL 9011 Black, Ø 7.6mm 80°C, EN 50290-2-24
Proposal form

    TAGS: SL400 SF/U23
    Comments

    No comments yet. You can be the first filling the form below.