Contents
General Details
Operating temperature | -30 °C… +70 °C |
Bending radius min. | 10xD |
Impedance | 75 ±3 Ω |
Capacity | 54 ± 2 pF/m |
Propagation speed | %82±2 |
Insulation resistance min. | 2 G Ω x km |
Operating voltage max. | 1000V |
Test voltage | 2500 V |
Attenuation @20 °C | 50 MHz 5,95dB/100m 200 MHz 11,71 dB/100m 470 MHz 18,08 dB/100m 860 MHz 24,79 dB/100m 1000 MHz 26,85 dB/100m |
return loss | 5-470 MHz >20dB 470-1000M Hz >18dB |
Standards | TSE K 212 |
fire performance | Vertical flame propagation EN 60332-1-2 |
EU declaration of conformity | LVD Low Voltage Regulation 2014/35/ABRoHS Some Hazardous Substances Restriction of Use 2011/65/EU |
Usage areas
Cables with characteristic impedance of 75 ohms using physical foamed insulation technology are used in indoor and dry environments, CCTV CCTV camera applications. It provides simultaneous transmission of video, power, audio and control signals.
Cable Structure
Conductive | Electrolytic copper wire, 0 0.81 mm (AWG20) |
Insulation | Physically foamed PE, 0 3.70mm, 70°C, EN 50290-2-23 |
display | Cu-Pet foil min.100% coverage, Electrolytic copper wire braid |
Inner sheath | PVC, TM51 70°C, EN 50290-2-22 |
Conductive | Stranded copper wire, 0.75mm2, Class5, IEC 60228 |
Insulation | PVC, Black-Red, TI52 EN 50290-2-21 |
Conductive | Stranded copper wire, 0.50mm2, Class5, IEC 60228 |
Insulation | PVC, Yellow-Blue, TI52 EN 50290-2-21 |
Sheath | PVC – RAL 7001 Grey, TM51 70°C, EN 50290-2-22 |
Proposal form
Comments