28.09.2021
171
TRB 80

General Details

Technical Specifications

operating temperature-30 °C … +70 °C
Bending radius min.10 x D
Impedance75 ± 3 Ω
Capacity52 ± 2 pF/m
Propagation speed%85 ± 2
Insulation resistance min.2 G Ω x km
Operating voltage max.1300 V
Test voltage3000 V
StandardsEN 50117, IEC 61196
fire performanceVertical flame spread EN 60332-1-2
Satellite distribution cable usage length2150MHz – 49m
VHF/UHF distribution cable length860MHz – 100m
S-band cable TV distribution cable run length470MHz – 137m
Attenuation @20 °C max50 MHz 5,90 dB/100m
200 MHz 11,7 dB/100m
470 MHz 18,1 dB/100m
860 MHz 24,8 dB/100m
1000 MHz 26,8 dB/100m
2150 MHz 40,6 dB/100m
2400 MHz 43,2 dB/100m
3000 MHz 48,9 dB/100m
return loss5-470 MHz > 20 dB
470-1000MHz > 18 dB
1000-2000 MHz > 16 dB
2000-3000 MHz > 15 dB
Screen attenuation30-1000MHz ≥ 95 dB
1000-2000 MHz ≥ 85 dB
2000-3000 MHz ≥ 75 dB
Transfer impedance5-30MHz ≤ 2,5 mΩ/m
Shielding ClassClass A+

Usage areas      

It is designed for satellite and terrestrial broadcast distribution operating at 5-3000MHz in accordance with EN 50117 standards in CATV distribution networks. Used as distribution cable in indoor applications.

Cable Structure

ConductiveAnnealed copper wire Ø 0.81mm
InsulationPhysically foamed PE Ø 3,50mm
ScreenAl-Pet-Sy foil 100% coverage tinned copper wire braid 65% coverage Al-Pet foil 100% coverage
SheathWhite PVC Ø 4,90mm