Contents
General Details
Operating temperature | -30 °C… +70 |
Bending radius min. | 15xD |
Impedance | 75 ±3 O |
Capacity | 54 ± 2 pF/m |
Propagation speed | %83±2 |
Insulation resistance min. | 2 G O x km |
Operating voltage max. | 1000V |
Test voltage | 2500 V |
conductor resistance max. | 0,22 mm2 96 Ω/km 0,50 mm2 39 Ω/km |
Attenuation @20°C Max | 1 MHz 2,2 dB/100m 5 MHz 4,0 dB/100m 10MHz 5,4 dB/100m 20 MHz 7,3 dB/100m 30 MHz 8,8 dB/100m 50 MHz 11,2 dB/100m 100 MHz 15,6dB/100m |
Standards | TSEK 212 |
fire performance | Vertical flame propagation EN 60332-1-2 |
EU Declaration of Conformity | LVD Low Voltage Directive 2014/35/EU RoHS Some Hazardous Substances Restriction of Use 2011/65/EU |
Usage areas
Using physical foamed insulation technology, cables with characteristic impedance of 75 ohm are used in indoor and dry environments, CCTV CCTV camera applications. It provides simultaneous transmission of video, power, audio and control signals.
Cable Structure
conductive | Twisted copper wire, 7×0.20mm, Class5, IEC 60228 |
insulation | Physically foamed PE, 0 2.50mm, 70°C, EN 50290-2-23 |
Screen | Al-Pet foil min.100% coverage. aluminum wire mesh |
conductive | Stranded copper wire, 0.50mm2, Class5, IEC 60228 |
insulation | PVC, Black-Red, TI52 EN 50290-2-21 |
conductive | Stranded copper wire, 0.22mm2, Class5, IEC 60228 |
insulation | PVC, Yellow-Blue, TI52 EN 50290-2-21 |
Screen | Al-Pet foil min.100% coverage |
Sheath | PVC – RAL 7001 Grey, TM51 70°C, EN 50290-2-22 |
Proposal form
Comments