HDV 100 HFFR

28.09.2021
223
HDV 100 HFFR

General Details

Technical Specifications

Operating temperature-30 °C … +70 °C
Bending radius min.10 x D
Impedance75 ± 1 Ω
Capacity53 ± 1 pF/m
Propagation speed%83 ± 1
Insulation resistance min.2 G Ω x km
Operating voltage max.1300 V
Test voltage3000 V
StandardsEN 50117, IEC 61196
fire performanceVertical flame spread EN 60332-1-2 Corrosive gas EN 50267-2-1/2 Smoke density EN 61034-2
data rateSD- 270 Mb/s
HD-1,5 Gb/s
3G-3,0 Gb/s
Std.SD- SMPTE 292M
HD-SMPTE 259M
3G-SMPTE 424M
ApplicationSD- Component SDI
HD-720p-1080i
3G-1080p
Kul. Uz.SD- 435 metre
HD-120 metre
3G-80 metre
Attenuation @20 °C max1 MHz 1,00 dB/100m
5 MHz 1,75 dB/100m
10 MHz 2,32 dB/100m
50 MHz 4,74 dB/100m
100 MHz 6,60 dB/100m
200 MHz 9,29 dB/100m
500 MHz 14,82 dB/100m
800 MHz 18,97 dB/100m
1000 MHz 21,37 dB/100m
1500
Hz 26,64 dB/100m
2250 MHz 33,36 dB/100m
3000 MHz 39,26 dB/100m
3500 MHz 42,90 dB/100m
4000 MHz 46,35 dB/100m
4500 MHz 49,65 dB/100m
5000 MHz 52,83 dB/100m
return loss5-300 MHz > 26 dB
300-3000MHz > 22 dB
3000-5000 MHz > 15 dB

Usage areas

Using physical foamed insulation technology, cables with 75 ohm characteristic impedance are used in live broadcast and studio applications such as sports competitions, as they carry rich media content such as HD and 3G uninterruptedly in Digital video, HDTV-SDI video transmission, in accordance with EN 50117 standards.

Cable Structure

ConductiveElectrolytic copper wire, Ø 1.02mm (AWG18) Class 1, IEC 60228
InsulationPhysically foamed PE, Ø 4,60mm 70°C, EN 50290-2-23
ScreenAl-Pet-Al foil min. 100% coverage tinned copper wire braid 95% coverage
SheathHFFR – RAL4007 Purple, Ø 6,90mm 70°C, EN 50290-2-27

Proposal form

    TAGS: HDV 100 HFFR
    Comments

    No comments yet. You can be the first filling the form below.