Technical Specifications

Operating temperature-30 °C … +70 °C
Bending radius min.10 x D
Impedance75 ± 1 Ω
Capacity54 ± 1 pF/m
Propagation speed%83 ± 1
Insulation resistance min.2 G Ω x km
Operating voltage max.1000 V
Test voltage2500 V
StandardsEN 50117, IEC 61196
fire performanceVertical flame spread EN 60332-1-2 Corrosive gas EN 50267-2-1/2 Smoke density EN 61034-2
data rateSD- 270 Mb/s
HD-1,5 Gb/s
3G-3,0 Gb/s
Std.SD- SMPTE 292M
HD-SMPTE 259M
3G-SMPTE 424M
ApplicationSD- Component SDI
HD-720p-1080i
3G-1080p
Kul. Uz.SD- 340 meter
HD-95 meter
3G-65 meter
Attenuation @20 °C max1 MHz 1,17 dB/100m
5 MHz 2,13 dB/100m
10 MHz 2,86 dB/100m
50 MHz 5,95 dB/100m
100 MHz 8,31 dB/100m
200 MHz 11,71 dB/100m
500 MHz 18,67 dB/100m
800 MHz 23,86 dB/100m
1000 MHz 26,85 dB/100m
1500
Hz 33,37dB/100m
2250 MHz 41,65 dB/100m
3000 MHz 48,87 dB/100m
3500 MHz 53,30 dB/100m
4000 MHz 57,50 dB/100m
4500 MHz 61,50 dB/100m
5000 MHz 65,35 dB/100m
return loss5-300 MHz > 26 dB
300-3000MHz > 22 dB
3000-5000 MHz > 15 dB

Usage areas

Using physical foamed insulation technology, cables with 75 ohm characteristic impedance are used in live broadcast and studio applications such as sports competitions, as they carry rich media content such as HD and 3G uninterruptedly in Digital video, HDTV-SDI video transmission, in accordance with EN 50117 standards.

Cable Structure

ConductiveElectrolytic copper wire, Ø 0.81mm (AWG20) Class 1, IEC 60228
InsulationPhysically foamed PE, Ø 3,70mm 70°C, EN 50290-2-23
ScreenAl-Pet-Al foil min. 100% coverage tinned copper wire braid 95% coverage
SheathHFFR – RAL4007 Purple, Ø 5.90mm 70°C, EN 50290-2-27
Proposal form