General Details
temperature range | constant:-30 °C… +70 °C active: 0 °C… +50 °C |
bending radius min. | constant min. : 7,5 x D active min. : 15 x D |
Conductor resistance | 0,22 mm2 max. 96,0 Ω/km 0,50 mm2 max. 39,0 Ω/km 0,75 mm2 max. 26,0 Ω/km 1,0 mm2 max. 19,5 Ω/km 1,5 mm2 max. 13,2 Ω/km 2,5 mm2 max. 7,98 Ω/km |
Insulation resistance min. | 200MΩx km |
Test voltage | 0,22 mm2 1200 V 0,50 mm2 1200 V 0,75 mm2 1200 V 1,0 mm2 1200 V 1,5 mm2 2500 V 2,5 mm2 2500 V |
Operating voltage max. | 300 V |
Standards | TSE K 353, DIN VDE 0812 |
fire performance | Vertical flame spread EN 60332-1-2 |
EU declaration of conformity | LVD Low Voltage Regulation 2014/35/EU RoHS Restriction of Use of Certain Hazardous Substances 2011/65/EU |
Usage areas
PVC insulated and sheathed cable is used as signal transmission cable in indoor environments. Thanks to its flexible and thin structures, it provides advantages in narrow space applications. It is used in industrial electronics, computer and office machines, indoor communication, sound and security systems. The cable, which has a static screen, is protected against external signals.
Cable Structure
Conductive | Stranded copper wire Class 5, IEC 60228 |
Insulation | PVC in accordance with DIN 47100 insulation color coding TI52 EN 50290-2-21, YI2 DIN VDE 0207-4 |
separator tape | Pet tape min. 100% coverage |
Screen | Tinned copper wire mesh |
Sheath | PVC – RAL 7001 Gray TM51 EN 50290-2-22, YM1 DIN VDE 0207-5 |
Proposal form