General Details

temperature range-20 °C… +70 °C
Bending radius min.15 x D
Loop resistance max.110Ω/km
Screen resistance nom.9Ω/km
Insulation resistance min.5000MΩx m
capacitance nom.28,5pF/m
characteristic impedance150 ± 15 Ω
Propagation speed78%
Test voltage1500 V
Operating voltage max.300 V
Attenuation @20 °C max.9,6 kHz 0,30 dB/100m
38,4 kHz 0,40 dB/100m
4 MHz 2,20 dB/100m
16 MHz 4,20 dB/100m
StandardsIEC 61158, EN 50170
fire performanceVertical flame spread EN 60332-1-2 (LSZH-PVC) Corrosive gas EN 60754-1/2 (LSZH) Smoke density EN 61034-2 (LSZH)
EU declaration of conformityLVD Low Voltage Regulation 2014/35/ABRoHS Some Hazardous Substances Restriction of Use 2011/65/EU

Usage areas                 

It effectively provides high-speed data transmission in industrial automation applications. Since master/slave connection is made over a single bus cable, it is easy to install and cost-effective.

IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T

IEEE 802.5 16MB; ISDN; TPDDI; ATM

Power over Ethernet (PoE) / PoE+

Cable Structure

ConductiveElectrolytic copper wire, Ø 22AWG
InsulationPhysically foamed PE, Ø 2.55mm, a(N) wire – green / b(P) wire – red 70°C, EN 50290-2-23
Inner SheathPVC – Natural, Ø 5,50mm LSZH/LS0H – Natural, Ø 5,50mm
ScreenAl-Pet foil min.100% coverage Tinned copper wire braid 85% coverage
SheathPVC – RAL 4001 Purple, Ø 8,0mm
TM51 70°C, EN 50290-2-22
LSZH/LS0H – RAL4001 Purple, Ø 8,0mm
70°C, EN 50290-2-27