General Details
Technical Specifications
Operating temperature | -30 °C … +70 °C |
Bending radius min. | 10 x D |
Impedance | 75 ± 3 Ω |
Capacity | 52 ± 2 pF/m |
Propagation speed | %85 ± 2 |
Insulation resistance min. | 2 G Ω x km |
Operating voltage max. | 2000 V |
Test voltage | 5000 V |
Standards | EN 50117, IEC 61196 |
fire performance | Vertical flame spread EN 60332-1-2 |
Satellite distribution cable usage length | 2150MHz – 90m |
VHF/UHF distribution cable length | 860MHz – 230m |
S-band cable TV distribution cable run length | 470MHz – 310m |
Attenuation @20 °C max | 50 MHz 3,15 dB/100m 200 MHz 6,18 dB/100m 470 MHz 9,60 dB/100m 860 MHz 13,29 dB/100m 1000 MHz 14,43 dB/100m 2150 MHz 22,25 dB/100m 2400 MHz 23,73 dB/100m 3000 MHz 27,06 dB/100m |
return loss | 5-470 MHz > 23dB 470-1000MHz > 20 dB 1000-2000 MHz > 18 dB 2000-3000 MHz > 16 dB |
Screen Attenuation | 30-1000 MHz ≥ 95 dB 1000-2000MHz ≥ 85 dB 2000-3000 MHz ≥ 75 dB |
Transfer Impedance | 5-30 MHz ≤ 2,5 mΩ/m |
Usage areas
Using physical foamed insulation technology, cables with 75 ohm characteristic impedance are used in Cable TV, individual-central antenna and satellite distribution systems and CCTV security camera systems in accordance with EN 50117 standards. The sheath material being polyethylene is preferred in open air and underground applications..
Cable Structure
Conductive | Elektrolitik bakır tel, Ø 1,63mm (AWG14) Class 1, IEC 60228 |
Insulation | orange, Physical foamed PE, Ø 7,11mm 70°C, EN 50290-2-23 |
Screen | Cu-Pet foil min.100% coverage electrolytic copper wire braid Cu-Pet foil min.100% coverage |
Sheath | LLDPE – RAL 9011 Black, Ø 10,0mm 80°C, EN 50290-2-24 |
Proposal form