RG 58 C/U

28.09.2021
179
RG 58 C/U

General Details

Technical Specifications

Operating temperature-30 °C … +70 °C
Bending radius min.10 x D
Impedance50 ± 3 Ω
Capacity101 ± 2 pF/m
Propagation speed%66 ± 2
Insulation resistance min.2 G Ω x km
Operating voltage max.2000 V
Test voltage5000 V
StandardsMIL-C-17F, MIL-C-17G
fire performanceVertical flame spread EN 60332-1-2 (PVC-HFFR) Corrosive gas EN 50267-2-1/2 (HFFR) Smoke density EN 61034-2 (HFFR)
Attenuation @20 °C max1 MHz 1,33 dB/100m
10 MHz 4,41 dB/100m
50 MHz 10,69 dB/100m
100 MHz 16,00 dB/100m
200 MHz 24,38 dB/100m
400 MHz 38,00 dB/100m
700 MHz 55,39 dB/100m
900 MHz 66,00 dB/100m
1000 MHz 71,11 dB/100m

Weakening = 1,30 * f(MHz) + 0,03*f(MHz)

Usage areas

Cables with 50 ohm characteristic impedance are used in radio and wireless communication systems, RFID, WiFi, Distributed antenna systems (DAS), Wireless internet (WISP), Global positioning (GPS) systems, defense industry and telecommunication systems in accordance with MIL-C-17 standards. While the sheath material is polyethylene, it is preferred in open air and underground applications, while it is preferred in places where it is halogen-free and should not be affected by fire conditions..

Cable Structure

ConductiveTwisted tinned copper wire, 19×0.18mm (AWG20) Class 5, IEC 60228
InsulationLDPE, Ø 2,95mm
70°C, EN 50290-2-23
ScreenTinned copper wire braid, 95% coverage
SheathPVC – RAL 9011 Black, Ø 4.95mm TM51 70°C, EN 50290-2-22 LLDPE – RAL 9011 Black, Ø 4.95mm 80°C, EN 50290-2-24 HFFR – RAL 9011 Black, Ø 4.95mm 70°C, EN 50290-2-27
Proposal form

    TAGS: RG 58 C/U
    Comments

    No comments yet. You can be the first filling the form below.