General Details
Technical Specifications
Operating temperature | -30 °C … +70 °C |
Bending radius min. | 10 x D |
Impedance | 50 ± 3 Ω |
Capacity | 101 ± 2 pF/m |
Propagation speed | %66 ± 2 |
Insulation resistance min. | 2 G Ω x km |
Operating voltage max. | 2000 V |
Test voltage | 5000 V |
Standards | MIL-C-17F, MIL-C-17G |
fire performance | Vertical flame spread EN 60332-1-2 (PVC-HFFR) Corrosive gas EN 50267-2-1/2 (HFFR) Smoke density EN 61034-2 (HFFR) |
Attenuation @20 °C max | 1 MHz 1,33 dB/100m 10 MHz 4,41 dB/100m 50 MHz 10,69 dB/100m 100 MHz 16,00 dB/100m 200 MHz 24,38 dB/100m 400 MHz 38,00 dB/100m 700 MHz 55,39 dB/100m 900 MHz 66,00 dB/100m 1000 MHz 71,11 dB/100m |
Weakening = 1,30 * f(MHz) + 0,03*f(MHz)
Usage areas
Cables with 50 ohm characteristic impedance are used in radio and wireless communication systems, RFID, WiFi, Distributed antenna systems (DAS), Wireless internet (WISP), Global positioning (GPS) systems, defense industry and telecommunication systems in accordance with MIL-C-17 standards. While the sheath material is polyethylene, it is preferred in open air and underground applications, while it is preferred in places where it is halogen-free and should not be affected by fire conditions..
Cable Structure
Conductive | Twisted tinned copper wire, 19×0.18mm (AWG20) Class 5, IEC 60228 |
Insulation | LDPE, Ø 2,95mm 70°C, EN 50290-2-23 |
Screen | Tinned copper wire braid, 95% coverage |
Sheath | PVC – RAL 9011 Black, Ø 4.95mm TM51 70°C, EN 50290-2-22 LLDPE – RAL 9011 Black, Ø 4.95mm 80°C, EN 50290-2-24 HFFR – RAL 9011 Black, Ø 4.95mm 70°C, EN 50290-2-27 |
Proposal form