General Details
Technical Specifications
Operating temperature | -30 °C … +70 °C |
Bending radius min. | 10 x D |
Impedance | 75 ± 3 Ω |
Capacity | 52 ± 2 pF/m |
Propagation speed | %84 ± 2 |
Insulation resistance min. | 2 G Ω x km |
Operating voltage max. | 1300 V |
Test voltage | 3000 V |
Standards | EN 50117, IEC 61196 |
fire performance | Vertical flame spread EN 60332-1-2 Corrosive gas EN 50267-2-1/2 Smoke density EN 61034-2 |
Satellite distribution cable usage length | 2150MHz – 60m |
VHF/UHF distribution cable length | 860MHz – 150m |
S-band cable TV distribution cable run length | 470MHz – 210m |
Attenuation @20 °C max | 50 MHz 4,74 dB/100m 200 MHz 9,29 dB/100m 470 MHz 14,35 dB/100m 860 MHz 19,72 dB/100m 1000 MHz 21,37 dB/100m 2150 MHz 32,52 dB/100m 2400 MHz 34,59 dB/100m 3000 MHz 39,26 dB/100m |
return loss | 5-470 MHz > 20 dB 470-1000MHz > 18 dB 1000-2000 MHz > 16 dB 2000-3000 MHz > 15 dB |
Screen Attenuation | 30-1000 MHz ≥ 75 dB 1000-2000MHz ≥ 65 dB 2000-3000 MHz ≥ 55 dB |
Transfer Impedance | 5-30 MHz ≤ 50 mΩ/m |
Attenuation = 2,00 * f(MHz) + 0,05*f(MHz) + 4,3
Usage areas
Using physical foamed insulation technology, cables with 75 ohm characteristic impedance are used in Cable TV, individual-central antenna and satellite distribution systems and CCTV security camera systems in accordance with EN 50117 standards.
Halogen-free material is used in the cable structure (it does not receive and transmit the flame late, it does not create toxic gas and black smoke that hinders vision after combustion). It is used in buildings such as mass housing, hotels, shopping centers, smart buildings, where people are concentrated, especially in places that should not be affected by fire conditions.
Cable Structure
Conductive | Electrolytic copper wire, Ø 1.02mm (AWG18) Class 1, IEC 60228 |
Insulation | blue, PE with physical foam, Ø 4,60mm 70°C, EN 50290-2-23 |
Screen | Al-Pet foil min.100% coverage aluminum wire mesh |
Sheath | HFFR – RAL 9003 White, Ø 6,80mm 70°C, EN 50290-2-27 |
Proposal form