TRB 11 PE

28.09.2021
179
TRB 11 PE

General Details

Technical Specifications

Operating temperature-30 °C … +70 °C
Bending radius min.10 x D
Impedance75 ± 3 Ω
Capacity52 ± 2 pF/m
Propagation speed%85 ± 2
Insulation resistance min.2 G Ω x km
Operating voltage max.2000 V
Test voltage5000 V
StandardsEN 50117, IEC 61196
fire performanceVertical flame spread EN 60332-1-2
Satellite distribution cable usage length2150MHz – 90m
VHF/UHF distribution cable length860MHz – 230m
S-band cable TV distribution cable run length470MHz – 310m
Attenuation @20 °C max50 MHz 3,15 dB/100m
200 MHz 6,18 dB/100m
470 MHz 9,60 dB/100m
860 MHz 13,29 dB/100m
1000 MHz 14,43 dB/100m
2150 MHz 22,25 dB/100m
2400 MHz 23,73 dB/100m
3000 MHz 27,06 dB/100m
return loss5-470 MHz > 23 dB
470-1000MHz > 20 dB
1000-2000 MHz > 18 dB
2000-3000 MHz > 16 dB
Screen attenuation30-1000MHz ≥ 95 dB
1000-2000 MHz ≥ 85 dB
2000-3000 MHz ≥ 75 dB
Transfer impedance5-30MHz ≤ 2,5 mΩ/m

Usage areas

Using physical foamed insulation technology, cables with 75 ohm characteristic impedance are used in Cable TV, individual-central antenna and satellite distribution systems and CCTV security camera systems in accordance with EN 50117 standards. The sheath material being polyethylene is preferred in open air and underground applications.

Cable Structure       

ConductiveElectrolytic copper wire, Ø 1.63mm (AWG14) Class 1, IEC 60228
InsulationPhysically foamed PE, Ø 7,11mm 70°C, EN 50290-2-23
ScreenAl-Pet-Sy folyo %100 kapama
Screen Al-Pet-Sy foil 100% coverage tinned copper wire mesh Al-Pet foil 100% coverage
SheathLLDPE – RAL 9011 Black, Ø 10,3mm
80°C, EN 50290-2-24