TRB 120 Plus HF

28.09.2021
178
TRB 120 Plus HF

Technical Specifications

Operating temperature-30 °C … +70 °C
Bending radius min.10 x D
Impedance75 ± 3 Ω
Capacity52 ± 2 pF/m
Propagation speed%86 ± 2
Insulation resistance min.2 G Ω x km
Operating voltage max.1300 V
Test voltage3000 V
StandardsEN 50117, IEC 61196
fire performanceVertical flame spread EN 60332-1-2 Corrosive gas EN 50267-2-1/2 Smoke density EN 61034-2
Satellite distribution cable usage length2150MHz – 67m
VHF/UHF distribution cable length860MHz – 167m
S-band cable TV distribution cable run length470MHz – 230m
Attenuation @20 °C max50 MHz 4,30 dB/100m
200 MHz 8,40 dB/100m
470 MHz 13,0 dB/100m
860 MHz 18,0 dB/100m
1000 MHz 19,5 dB/100m
2150 MHz 29,7 dB/100m
2400 MHz 31,7 dB/100m
3000 MHz 36,0 dB/100m
return loss5-470 MHz > 23 dB
470-1000MHz > 20 dB
1000-2000 MHz > 18 dB
2000-3000 MHz > 16 dB
Screen attenuation30-1000MHz ≥ 95 dB
1000-2000 MHz ≥ 85 dB
2000-3000 MHz ≥ 75 dB
Transfer impedance5-30MHz ≤ 2,5 mΩ/m
Shielding ClassClass A+

Usage areas

It is designed for satellite and terrestrial broadcast distribution operating at 5-3000MHz in accordance with EN 50117 standards in CATV distribution networks. It is used as distribution cable in indoor applications.

It is used in buildings where people are densely populated, since halogen-free (does not transmit and transmit flames late, does not create toxic gas and black smoke that hinders vision) material is used in the cable structure.

Cable Structure

ConductiveAnnealed copper wire Ø 1.13mm
InsulationPhysically foamed PE Ø 4,80mm
ScreenAl-Pet-Sy foil 100% coverage tinned copper wire braid 80% coverage Al-Pet foil 100% coverage
SheathWhite PVC Ø 6,90mm