Technical Specifications
Operating temperature | -30 °C … +70 °C |
Bending radius min. | 10 x D |
Impedance | 75 ± 3 Ω |
Capacity | 52 ± 2 pF/m |
Propagation speed | %86 ± 2 |
Insulation resistance min. | 2 G Ω x km |
Operating voltage max. | 1300 V |
Test voltage | 3000 V |
Standards | EN 50117, IEC 61196 |
fire performance | Vertical flame spread EN 60332-1-2 Corrosive gas EN 50267-2-1/2 Smoke density EN 61034-2 |
Satellite distribution cable usage length | 2150MHz – 67m |
VHF/UHF distribution cable length | 860MHz – 167m |
S-band cable TV distribution cable run length | 470MHz – 230m |
Attenuation @20 °C max | 50 MHz 4,30 dB/100m 200 MHz 8,40 dB/100m 470 MHz 13,0 dB/100m 860 MHz 18,0 dB/100m 1000 MHz 19,5 dB/100m 2150 MHz 29,7 dB/100m 2400 MHz 31,7 dB/100m 3000 MHz 36,0 dB/100m |
return loss | 5-470 MHz > 23 dB 470-1000MHz > 20 dB 1000-2000 MHz > 18 dB 2000-3000 MHz > 16 dB |
Screen attenuation | 30-1000MHz ≥ 95 dB 1000-2000 MHz ≥ 85 dB 2000-3000 MHz ≥ 75 dB |
Transfer impedance | 5-30MHz ≤ 2,5 mΩ/m |
Shielding Class | Class A+ |
Usage areas
It is designed for satellite and terrestrial broadcast distribution operating at 5-3000MHz in accordance with EN 50117 standards in CATV distribution networks. It is used as distribution cable in indoor applications.
It is used in buildings where people are densely populated, since halogen-free (does not transmit and transmit flames late, does not create toxic gas and black smoke that hinders vision) material is used in the cable structure.
Cable Structure
Conductive | Annealed copper wire Ø 1.13mm |
Insulation | Physically foamed PE Ø 4,80mm |
Screen | Al-Pet-Sy foil 100% coverage tinned copper wire braid 80% coverage Al-Pet foil 100% coverage |
Sheath | White PVC Ø 6,90mm |
Proposal form
Comments